Concept Guide

19 Memory Errors and Dell PowerEdge YX4X Server Memory RAS Features
the CE rate detection scheme associated with the MEM8000 event. However, the improvement
resulted in an uptick in MEM8000 events that were not substantiated by results from memory
component failure analysis. With this PowerEdge server BIOS update, the following changes
have been made:
o Signaling of the MEM8000 event has been modified
o PowerEdge server BIOS may schedule self-healing to occur on the identified DIMM
Dell Technologies continues to investigate opportunities to improve the detection scheme
related to an MEM8000 event.