Setup Guide
Server Configuration Profiles: User’s Guide
22 Server Configuration Profiles: Reference Guide | 456
racadm>>lclogviewconfigresult‐jJID_898317921404
SeqNumber=5008
FQDD=iDRAC.Embedded.1
JobName=ImportConfiguration
OperationName=CHANGE
DisplayValue=SSHIdleTimeout
Name=SSH.1#Timeout
OldValue=1800
NewValue=1805
Status=Success
ErrCode=0
Refer to the Event and Error Message Reference Guide to locate the Recommended Response Action to a
specific error code.
Error code lookup can also be performed using this tool:
https://qrl.dell.com/LCDError/Lookup?q=ErrorCode
4.1 Host Reboot
The SCP Import operation may automatically restart the host to apply all settings, but only if the template
contains settings that require a host reboot. As an example, if an SCP Import was performed and only iDRAC
settings changes were detected then the host reboot would not be performed.
NOTE: The SCP Import operation may reboot multiple times to apply all configuration settings and
firmware.
4.1.1 What will trigger a reboot?
The following components will trigger a reboot.
BIOS.Setup.1-1
All network (NIC, FC, InfiniBand) components.
All storage components.
The following components will not trigger a reboot.
iDRAC.Embedded.1
System.Embedded.1
LifecycleController.Embedded.1 excluding BIOSRequestRTD.
EventFilters
SupportAssist
The SCP Import Preview operation will indicate if a template requires a host reboot in the configuration results
without applying settings or triggering a reboot.
racadm>>lclogviewconfigresult‐jJID_040778842537
SeqNumber=10365
JobName=PreviewConfiguration
MessageID=SYS087