Owner's Manual

* Devices that are disabled in the operating system are not
inventoried or updated by SUU. To update or inventory these devices,
enable the devices in the operating system and then relaunch SUU.
(142111)
* Do not use the RAC virtual media to run SUU remotely on a system.
This procedure breaks the virtual media connection, causing the SUU
update procedure to fail. (144487)
* SUU fails if it is run from a pathname that contains special
characters. For example, ",:,/,\,$, etc. It is recommended to use
a directory name without any special characters for running
SUU. As an example, a case where you can get directory name
with special characters is:
In the SUSE Linux Enterprise Server operating system, when a
USB DVD-ROM or USB disk is attached, it may by default, mount
to a directory name that contains special characters. For
example, /media/USB:1:2/ (42279)
* If a RAC DUP package (RAC 4/P or RAC 4/i) is running and SUU is
started, the RAC package may fail. To resolve this issue, run SUU
only after the RAC package has completed execution. (23184)
* In Linux, if there is not enough space in the var partition or tmp
folder, SUU displays the following error message:
"Not enough space available in the /var or /tmp folder. Please
ensure you have atleast 100MB."
Ensure that you have sufficient space in the var partition or tmp
folder and restart SUU to start the system inventory. (66118)
* In some cases where the latest Intel NIC driver (Intel(R) PRO
PCIE Gigabit Family of Adapters 9.5, base driver version 9.6.31.0)
is installed as part of Dell Systems Build and Update Utility
(SBUU) install, SUU may not be able to inventory the respective
NIC. This may happen because SBUU would not have installed the
umbrella software. In these cases, install the umbrella with the
umbrella installer (available at support.dell.com or in the SERVICE
directory on the Dell Systems Management Tools and Documentation
DVD) to get the Intel NIC inventoried by SUU (DF130363).
* SUU may fail to launch on Xenserver 5.6 if the lockfile dependency
is not met. To fix this issue, install the procmail rpm:
procmail-3.22-17.1.el5.centos.i386.rpm
* If you use a Microsoft Windows Server 2003 operating system
platform, you require .Net Framework 2.0 to run
Dell_PV_Utils_NASDUP.exe. If .Net Framework 2.0 is not installed,
0xc0000135 error code may be encountered.
#####################################################################
THIRD PARTY DISCLAIMER
#####################################################################
The following disclaimer applies to the "TreeTable" control code in
IT Assistant: