Release Notes

Important Notes
DUPs for Dell Lifecycle Controller OS Driver packs are no longer available on the Dell OpenManage
Server Update ISO. You can find them on Dell Lifecycle Controller OS Driver Packs ISO.
The below information helps enhance your experience with SUU in specific implementations and
environments.
If you launch SUU from a command shell and then press <Ctrl><C>, the SUU procedure, as well
as any running updates, will terminate.(137862)
When you launch SUU, depending on the system configuration the inventory collection process
takes few minutes , delaying the display of system comparison report.(138439)
The figures and examples in the "Dell OpenManage Server Update Utility User's Guide" are used
as examples only and may not be identical to the SUU GUI.(137294,136624)
When you verify the SUU return codes, use the operating system-specific commands to view the
exit codes.(137296)
For example:
Microsoft Windows: echo %ERRORLEVEL%
Red Hat Enterprise Linux: echo $?
Known Issues and Resolutions
VRTX M520 is displayed as M520 in SUU Comparison report.
VRTX M620 is displayed as M620 in SUU Comparison report.
The BIOS package is not available for T105 platform. (BITS089778)
When you run the SATA hard disk update on Microsoft Windows 2012 Standard operating
system with 16GB configuration, the update is unsuccessful. (BITS053783)
When you run the hard disk update (52P2Y) on Microsoft Windows 2012 operating system, it is
unsuccessful (BITS054325)
Refer the PSQN ID , ID:596787: Device Buffer error when running hard drive SATA DUP
under Microsoft Windows Server 2012 for BITS053783 and BITS054325.
If your CERC ATA RAID controllers are configured with the H661 firmware, SUU cannot update
the firmware to the latest version.
To update the firmware, use the "-force" option to manually apply the DUP with the latest
firmware version. (134775)
When updating multiple, identical devices on the same system, SUU applies the latest update to
all instances of all devices. For example, if the system is configured with three controllers
configured with firmware or driver versions 1.2, 1.3, and 1.4, and the repository version is 1.4, SUU
applies version 1.4 to all instances of all devices.(136620)
When you run SUU using the "-p" option, SUU reports the current instance log location ("suu -p")
instead of the SUU instance log location ("suu -u") that is performing the update.(135925)
SUU uses DUPs to update various system components. During a Red Hat Enterprise Linux update,
the DUPs create a "/var/lock/.spsetup" file using the Linux lockfile utility during the initial
execution procedure. Kernel panics or sudden reboots during DUP execution (reboots where
TERM signals are not sent to running processes or where running processes do not track these