Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
reassigned during a
write operation
contains bad disk
blocks that could
not be reassigned.
Data loss may have
occurred.
2350 There was an
unrecoverable disk
media error during
the rebuild or
recovery operation
Critical The rebuild or
recovery operation
encountered an
unrecoverable disk
media error.
Restrict
2355 Enclosure firmware
download failed.
Warning The system was
unable to download
firmware to the
enclosure. The
controller may have
lost communication
with the enclosure.
There may have
been problems with
the data transfer or
the download
media may be
corrupt.
Restrict and Migrate
2356 SAS SMP
communications
error
Critical The text for this
alert is generated by
the firmware and
can vary depending
on the situation.
The reference to
SMP in this text
refers to SAS
Management
Protocol.
Restrict
2357 SAS expander error Critical There may be a
problem with the
enclosure. Verify
the health of the
enclosure and its
components.
Restrict
2387 Virtual disk bad
block medium
error is detected
Error Virtual disk bad
blocks are due to
presence of
Restrict and Migrate
31