Users Guide
Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
for other reasons.
The controller is
reinitializing the
NVRAM.
2328 The NVRAM has
corrupt data
Warning The NVRAM has
corrupt data. The
controller is unable
to correct the
situation.
Restrict and Migrate
2329 SAS port report Warning The text for this
alert is generated by
the controller and
can vary depending
on the situation.
Restrict and Migrate
2337 The controller is
unable to recover
cached data from
the battery backup
unit (BBU)
Critical The controller was
unable to recover
data from the
cache.
Restrict
2340 The background
initialization (BGI)
completed with
uncorrectable
errors
Critical The background
initialization task
encountered errors
that cannot be
corrected.
Restrict and Migrate
2342 The Check
Consistency found
inconsistent parity
data. Data
redundancy may be
lost
Warning The data on a
source disk and the
redundant data on a
target disk are
inconsistent.
Restrict and Migrate
2347 The rebuild failed
due to errors on
the source physical
disk
Error It is not possible to
rebuild data that
resides on a
defective disk.
Restrict and Migrate
2348 The rebuild failed
due to errors on
the target physical
disk.
Error It is not possible to
rebuild data that
resides on a
defective disk.
Restrict and Migrate
2349 A bad disk block
could not be
Critical A write operation
could not complete
because the disk
Restrict
30