Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
Failed or Degraded
state.
2302 The enclosure is
not responding
Critical The enclosure or an
enclosure
component is in a
Failed or Degraded
state.
Restrict and Migrate
2306 Bad block table is
80% full
Warning The bad block table
is the table used for
remapping bad disk
blocks. This table
fills as bad disk
blocks are
remapped.
Restrict
2307 Bad block table is
full.
Critical The bad block table
is the table used for
remapping bad disk
blocks.
Restrict
2310 A virtual disk is
permanently
degraded
Critical A redundant virtual
disk has lost
redundancy. This
may occur when
the virtual disk
suffers the failure of
more than one
physical disk.
Restrict and Migrate
2312 A power supply in
the enclosure has
an AC failure
Warning The power supply
has an AC failure.
Restrict
2313 A power supply in
the enclosure has a
DC failure
Warning The power supply
has a DC failure.
Restrict
2314 The initialization
sequence of SAS
components failed
during system
startup. SAS
management and
monitoring is not
possible.
Critical Storage
Management is
unable to monitor
or manage SAS
devices.
Restrict and Migrate
28