Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
battery may have
been already
recharged the
maximum number
of times. In
addition, the battery
charger may not be
working.
2171 The controller
battery
temperature is
above normal
Warning The room
temperature may
be too hot. The
system fan may also
be degraded or
failed.
Restrict
2174 The controller
battery has been
removed
Warning The controller
cannot
communicate with
the battery. The
battery may be
removed or the
contact point maye
degraded
Restrict and Migrate
2178 The controller
battery Learn cycle
has timed out
Warning The controller
battery must be
fully charged before
the Learn cycle can
begin.
Restrict
2187 Single-bit ECC
error limit
exceeded on the
controller DIMM
Warning The controller
memory is
malfunctioning.
Restrict and Migrate
2201 A global hot spare
failed
Warning The controller is not
able to
communicate with
a disk that is
assigned as a global
hot spare. The disk
may have failed or
been removed.
Restrict
2203 A dedicated hot
spare failed
Warning The controller is not
able to
communicate with
Restrict
24