Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
the excessive
temperature.
2103 Temperature
dropped below the
Minimum Failure
Threshold
Critical The physical disk
enclosure is too
cool.
Restrict and Migrate
2112 Enclosure
shutdown
Critical The physical disk
enclosure is either
hotter or cooler
than the maximum
or minimum
allowable
temperature range.
Restrict and Migrate
2122 Redundancy
degraded
Warning One or more of the
enclosure
components has
failed. For example,
a fan or power
supply may have
failed.
Restrict
2123 Redundancy Lost Warning A virtual disk or an
enclosure has lost
data redundancy.
Restrict and Migrate
2125 Controller cache
pinned for missing
or offline VD
Warning Controller getting
disconnected from
its VD, while IO is
happening
Restrict
2129 BGI (Back Ground
Initialization) Failed
Error
Critical BGI of a virtual disk
has failed.
Restrict
2137 Communication
Time-out Warning
Warning The controller is
unable to
communicate with
an enclosure.
Restrict and Migrate
2145 Controller battery
low
Warning The controller
battery charge is
low.
Restrict
2169 The controller
battery needs to be
replaced
Critical The controller
battery cannot
recharge. The
Restrict and Migrate
23