2056 Virtual Disk Failed Critical One or more
physical disks
included in the
virtual disk have
failed.
Restrict and Migrate
2057 Virtual Disk
Degraded Warning
Warning This alert message
occurs when a
physical disk
included in a
redundant virtual
disk fails.
Restrict
2076 Virtual Disk Check
Consistency Failed
Critical A physical disk
included in the
virtual disk failed or
there is an error in
the parity
information.
Restrict and Migrate
2082 Virtual Disk Rebuild
Failure
Critical A physical disk
included in the
virtual disk has
failed or is corrupt.
Restrict
2083 Physical Disk
Rebuild Failed
Critical A physical disk
included in the
virtual disk has
failed or is corrupt.
Restrict
2094 Predictive Failure
reported
Warning The physical disk is
predicted to fail.
Restrict
2100 Temperature
exceeded
Maximum Warning
Threshold
Warning The physical disk
enclosure is too
hot. A variety of
factors can cause
the excessive
temperature.
Restrict
2101 Temperature
dropped below
Minimum Warning
Threshold
Warning The physical disk
enclosure is too
cool.
Restrict
2102 Temperature
exceeded
Maximum Failure
Threshold
Critical The physical disk
enclosure is too
hot. A variety of
factors can cause
Restrict and Migrate
22