Users Guide
Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
previous state and
processor sensor
status are provided.
1703;5703 Battery sensor
detected a warning
value
Warning A battery sensor in
the specified
system detected
that a battery is in
a predictive failure
state.
Restrict
1704;5704 Battery sensor
detected a failure
value
Error A battery sensor in
the specified
system detected
that a battery has
failed. The sensor
location, chassis
location, previous
state, and battery
sensor status
information is
provided.
Restrict
1705;5705 Battery sensor
detected a non-
recoverable value
Error A battery sensor in
the specified
system could not
retrieve a value. The
sensor location,
chassis location,
previous state, and
battery sensor
status information is
provided.
Restrict
2048 Device Failed Error Critical A storage
component such as
a physical disk or an
enclosure has
failed. The failed
component may
have been identified
by the controller
while performing a
task such as a
rescan or a check
consistency.
Restrict and Migrate
21