Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
because of an
irrecoverable error.
1453;5453 Fan enclosure
removed from
system
Warning A fan enclosure has
been removed from
the specified
system. The sensor
and chassis location
information is
provided.
Restrict
1454;5454 Fan enclosure
removed from
system for an
extended amount
of time
Error A fan enclosure has
been removed from
the specified
system for a user-
definable length of
time. The sensor
and chassis location
information is
provided.
Restrict and Migrate
1455;5455 Fan enclosure
sensor detected a
non-recoverable
value
Error A fan enclosure
sensor in the
specified system
detected an error
from which it
cannot recover. The
sensor and chassis
location are
provided.
Restrict and Migrate
1503;5503 AC power has been
lost
Error An AC power cord
has lost its power,
and lack of
redundancy
requires this to be
classified as an
error.
Restrict and Migrate
1504;5504 AC power cord has
lost its power
Error Power supply is
disrupted to the AC
power cord or an
AC power cord is
not transmitting
power, and lack of
redundancy
requires this to be
Restrict and Migrate
19