Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
1353;5353 Power supply
detected a warning
Warning A power supply
sensor reading in
the specified
system exceeded
definable warning
threshold.
Restrict
1354;5354 Power supply
detected a failure
Error A power supply has
been disconnected
or has failed.
Restrict
1355;5355 Power supply
sensor detected a
non-recoverable
value
Error A power supply
sensor in the
specified system
detected an error
from which it
cannot recover. The
sensor location,
chassis location,
previous state,
power supply type,
additional power
supply status, and
configuration error
type information is
provided.
Restrict
1403;5403 Memory Device
Status Warning
Warning A memory device
correction rate
exceeded an
acceptable value.
Restrict
1404;5404 Memory Device
Error
Error A memory device
correction rate
exceeded an
acceptable value, a
memory spare bank
was activated, or a
multibit ECC error
occurred.
Restrict and Migrate
1405;5405 Memory device
status is non-
recoverable
Error Memory device
status is
nonrecoverable.
The memory
module failed
Restrict and Migrate
18