Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
value information is
provided.
1104;5104 Fan sensor
detected a failure
value
Error A fan sensor in the
specified system
detected the failure
of one or more
fans.
Restrict
1105;5105 Fan sensor
detected a non-
recoverable value
Error A fan sensor
detected an error
from which it
cannot recover. The
sensor location,
chassis location,
previous state, and
fan sensor value
information is
provided.
Restrict
1153;5153 Voltage sensor
detected a warning
value
Warning A voltage sensor in
the specified
system exceeded its
warning threshold.
The sensor location,
chassis location,
previous state, and
voltage sensor
value information is
provided.
Restrict
1154;5154 Voltage sensor
detected a failure
value
Error A voltage sensor in
the specified
system exceeded its
failure threshold
value.
Restrict and Migrate
1155;5155 Voltage sensor
detected a non-
recoverable value
Error A voltage sensor in
the specified
system detected an
error from which it
cannot recover. The
sensor location,
chassis location,
previous state, and
voltage sensor
Restrict and Migrate