Users Guide

Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
configured, the
operating system
shuts down and the
system powers off.
This event may also
be initiated on
certain systems
when a fan
enclosure is
removed from the
system for an
extended period of
time.
1053;5053 Temperature
sensor detected a
warning value
Warning A temperature
sensor on the
backplane board,
system board, CPU,
or drive carrier in
the specified
system exceeded its
warning threshold
value.
Restrict
1054;5054 Temperature
sensor detected a
failure value
Error A temperature
sensor on the
backplane board,
system board, CPU,
or drive carrier in
the specified
system exceeded its
failure threshold
value.
Restrict and Migrate
1055;5055 Temperature
sensor detected a
non-recoverable
value
Error A temperature
sensor on the
backplane board,
system board, or
drive carrier in the
specified system
detected an error
from which it
cannot recover. The
sensor location,
chassis location,
previous state, and
temperature sensor
Restrict and Migrate
14