Users Guide

NOTE: When you select Enable, Operations Manager performs an auto-implementation for the
unit monitor. Since this involves VMM migration, review and set the values accordingly.
8. Select the Enforce option.
9. Click Apply
CAUTION: Saving the settings in the default management pack, creates a dependency
between PRO Pack and the management pack. When you remove or delete PRO Pack, you
must delete the default management pack as well, as it contains default settings for
Operations Manager. Hence, it is recommended that you save settings using a new MP.
10. Click OK .
11. Generate an alert and PRO Tip.
12. Select Implement PRO Tip.
This verifies that the overridden recovery action is successful.
Figure 2. Override Properties
Alerts and Recovery Actions
The following table lists the alerts and the recommended remedial actions:
Table 2. Alerts and Recovery Actions
Dell Event ID Alert Description
on Operations
Manager and PRO
Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
1004;5004 Thermal shutdown
protection has
been initiated
Error This message is
generated when a
system is
configured for
thermal shutdown
due to an error
event. If a
temperature sensor
reading exceeds the
error threshold for
which the system is
Restrict and Migrate
13