Users Guide

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
connected to the same
enclosure.
2289 Multi-bit ECC error on
controller DIMM
Critical An error involving
multiple bits has been
encountered during a
read or write
operation.
Restrict and Migrate
2290 Single-bit ECC error on
controller DIMM
Warning An error involving a
single bit has been
encountered during a
read or write
operation.
Restrict
2292 Communication with
the enclosure has
been lost
Critical The controller has lost
communication with
an enclosure
management module
(EMM). The cables
may be loose or
defective.
Restrict and Migrate
2293 EMM (Enclosure
Management Module)
Failure
Error The failure may be
caused by a loss of
power to the EMM.
Restrict and Migrate
2298 The enclosure has a
bad sensor
Warning The enclosure has a
bad sensor. The
enclosure sensors
monitor the fan
speeds, temperature
probes, and so on.
Restrict
2299 Bad PHY Critical There is a problem
with a physical
connection or PHY.
Restrict
2300 Unstable Enclosure
Failure
Critical The controller is not
receiving a consistent
response from the
enclosure.
Restrict and Migrate
2301 Enclosure Hardware
Error
Critical The enclosure or an
enclosure component
is in a Failed or
Degraded state.
Restrict and Migrate
2302 The enclosure is not
responding
Critical The enclosure or an
enclosure component
is in a Failed or
Degraded state.
Restrict and Migrate
20