Users Guide

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
2103 Temperature dropped
below the Minimum
Failure Threshold
Critical The physical disk
enclosure is too cool.
Restrict and Migrate
2112 Enclosure shutdown Critical The physical disk
enclosure is either
hotter or cooler than
the maximum or
minimum allowable
temperature range.
Restrict and Migrate
2122 Redundancy degraded Warning One or more of the
enclosure components
has failed. For
example, a fan or
power supply may
have failed.
Restrict
2123 Redundancy Lost Warning A virtual disk or an
enclosure has lost
data redundancy.
Restrict and Migrate
2125 Controller cache
pinned for missing or
offline VD
Warning Controller getting
disconnected from its
VD, while IO is
happening
Restrict
2129 BGI (Back Ground
Initialization) Failed
Error
Critical BGI of a virtual disk
has failed.
Restrict
2137 Communication Time-
out Warning
Warning The controller is
unable to
communicate with an
enclosure.
Restrict and Migrate
2145 Controller battery low Warning The controller battery
charge is low.
Restrict
2169 The controller battery
needs to be replaced
Critical The controller battery
cannot recharge. The
battery may have been
already recharged the
maximum number of
times. In addition, the
battery charger may
not be working.
Restrict and Migrate
2171 The controller battery
temperature is above
normal
Warning The room temperature
may be too hot. The
system fan may also
be degraded or failed.
Restrict
17