Users Guide

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
1204 Current sensor
detected a failure
value
Error A current sensor in the
specified system
exceeded its failure
threshold value.
Restrict and Migrate
1305 Redundancy degraded Warning A power supply sensor
reading in the
specified system
exceeded a warning
threshold.
Restrict
1306 Redundancy lost Error A power supply has
been disconnected or
has failed.
Restrict
1353 Power supply detected
a warning
Warning A power supply sensor
reading in the
specified system
exceeded definable
warning threshold.
Restrict
1354 Power supply detected
a failure
Error A power supply has
been disconnected or
has failed.
Restrict
1403 Memory Device Status
Warning
Warning A memory device
correction rate
exceeded an
acceptable value.
Restrict
1404 Memory Device Error Error A memory device
correction rate
exceeded an
acceptable value, a
memory spare bank
was activated, or a
multibit ECC error
occurred.
Restrict and Migrate
1703 Battery sensor
detected a warning
value
Warning A battery sensor in the
specified system
detected that a battery
is in a predictive
failure state.
Restrict
2048 Device Failed Error Critical A storage component
such as a physical disk
or an enclosure has
failed. The failed
component may have
been identified by the
Restrict and Migrate
15