User's Manual
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
controller is unable to
correct the situation
2329 SAS port report Warning The text for this alert is
generated by the
controller and can vary
depending on the
situation.
Restrict and Migrate
2337 The controller is
unable to recover
cached data from the
battery backup unit
(BBU)
Critical The controller was
unable to recover data
from the cache.
Restrict
2340 The background
initialization (BGI)
completed with
uncorrectable errors
Critical The background
initialization task
encountered errors
that cannot be
corrected.
Restrict and Migrate
2342 The Check
Consistency found
inconsistent parity
data. Data redundancy
may be lost
Warning The data on a source
disk and the redundant
data on a target disk is
inconsistent.
Restrict and Migrate
2349 A bad disk block could
not be reassigned
during a write
operation
Critical A write operation
could not complete
because the disk
contains bad disk
blocks that could not
be reassigned. Data
loss may have
occurred.
Restrict
2350 There was an
unrecoverable disk
media error during the
rebuild or recovery
operation
Critical The rebuild or
recovery operation
encountered an
unrecoverable disk
media error.
Restrict
2356 SAS SMP
communications error
Critical The text for this alert is
generated by the
firmware and can vary
depending on the
situation. The
reference to SMP in
this text refers to SAS
Management Protocol.
Restrict
22