User's Manual

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
monitoring is not
possible.
2318 Problems with the
battery or the battery
charger have been
detected. The battery
health is poor.
Warning The battery or the
battery charger is not
functioning properly.
Restrict
2319 Single-bit ECC error on
controller DIMM.
Warning The dual in-line
memory module
(DIMM) is beginning to
malfunction.
Restrict and Migrate
2320 Single-bit ECC error Critical The dual in-line
memory module
(DIMM) is
malfunctioning.
Restrict and Migrate
2321 Single-bit ECC error.
The controller DIMM is
nonfunctional. There
will be no further
reporting
Critical The dual in-line
memory module
(DIMM) is
malfunctioning. Data
loss or data corruption
is eminent.
Restrict and Migrate
2322 The DC power supply
is switched off
Critical The power supply unit
is switched off. Either
a user switched off the
power supply unit or it
is defective.
Restrict and Migrate
2324 The AC power supply
cable has been
removed
Critical The power cable may
be pulled out or
removed. The power
cable may also have
overheated and
become warped and
nonfunctional.
Restrict and Migrate
2327 The NVRAM has
corrupted data. The
controller is
reinitializing the
NVRAM
Warning The NVRAM has
corrupted data. This
may ocurr after a
power surge, a battery
failure, or for other
reasons. The controller
is reinitializing the
NVRAM
Restrict and Migrate
2328 The NVRAM has
corrupt data
Warning The NVRAM has
corrupt data. The
Restrict and Migrate
21