User's Manual
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
punctured by the
controller
error when attempting
to read a block on the
physical disk and
marked that block as
invalid.
2282 Hot spare SMART
polling failed
Critical The controller
firmware attempted to
do SMART polling on
the hot spare but was
not able to complete
the SMART polling.
Restrict and Migrate
2283 A redundant path is
broken
Warning The controller has two
connectors that are
connected to the same
enclosure.
Restrict and Migrate
2289 Multi-bit ECC error on
controller DIMM
Critical An error involving
multiple bits has been
encountered during a
read or write
operation.
Restrict and Migrate
2290 Single-bit ECC error on
controller DIMM
Warning An error involving a
single bit has been
encountered during a
read or write
operation.
Restrict
2292 Communication with
the enclosure has
been lost
Critical The controller has lost
communication with
an enclosure
management module
(EMM). The cables
may be loose or
defective.
Restrict and Migrate
2293 EMM (Enclosure
Management Module)
Failure
Error The failure may be
caused by a loss of
power to the EMM.
Restrict and Migrate
2298 The enclosure has a
bad sensor
Warning The enclosure has a
bad sensor. The
enclosure sensors
monitor the fan
speeds, temperature
probes, and so on.
Restrict
19