Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
2207 The only hot spare
available is a SAS disk.
SAS disks cannot
replace SATA disks
Warning The only physical disk
available to be
assigned as a hot
spare is using SAS
technology.
Restrict
2213 Recharge count
maximum exceeded
Warning A virtual disk or an
enclosure has lost
data redundancy. In
the case of a virtual
disk, one or more
physical disks included
in the virtual disk have
failed.
Restrict
2246 The controller battery
is degraded
Warning The temperature of the
the battery is high. This
maybe due to the
battery being charged.
Restrict
2264 A device is missing Warning The controller cannot
communicate with a
device. The device
may be removed.
Restrict
2265 A device is in an
unknown state
Warning The controller cannot
communicate with a
device. The state of
the device cannot be
determined.
Restrict and Migrate
2268 Storage Management
communication Error
Critical Storage Management
has lost
communication with a
controller. This may
occur if the controller
driver or firmware is
experiencing a
problem.
Restrict and Migrate
2272 Patrol Read found an
uncorrectable media
error
Critical The Patrol Read task
has encounted an
error that cannot be
corrected. There may
be a bad disk block
that cannot be
remapped.
Restrict and Migrate
2273 A block on the physical
disk has been
Critical The controller
encountered an
unrecoverable medium
Restrict and Migrate