User's Manual

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
during a write
operation
because the disk
contains bad disk
blocks that could not
be reassigned. Data
loss may have
occurred.
2350 There was an
unrecoverable disk
media error during the
rebuild or recovery
operation
Critical The rebuild or
recovery operation
encountered an
unrecoverable disk
media error.
Restrict
2356 SAS SMP
communications error
Critical The text for this alert is
generated by the
firmware and can vary
depending on the
situation. The
reference to SMP in
this text refers to SAS
Management Protocol.
Restrict
2357 SAS expander error Critical There may be a
problem with the
enclosure. Verify the
health of the enclosure
and its components.
Restrict
2387 Virtual disk bad block
medium error is
detected
Critical Virtual disk bad blocks
are due to presence of
unrecoverable bad
blocks on one or more
member physical disks
Restrict and Migrate
2396 The Check
Consistency detected
uncorrectable multiple
medium errors
Critical Medium errors in the
physical drives.
Restrict
2397 The Check
Consistency
completed with
uncorrectable errors
Critical Medium errors in the
physical drives.
Restrict and Migrate
2416 Disk medium error
detected
Warning Disk medium error
detected
Restrict
2417 There is an
unrecoverable medium
error detected on
virtual disk
Critical Unrecoverable
medium error detected
on virtual disk.
Restrict and Migrate
23