User's Manual
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
power supply unit or it
is defective.
2324 The AC power supply
cable has been
removed
Critical The power cable may
be pulled out or
removed. The power
cable may also have
overheated and
become warped and
nonfunctional.
Restrict and Migrate
2327 The NVRAM has
corrupted data. The
controller is
reinitializing the
NVRAM
Warning The NVRAM has
corrupted data. This
may ocurr after a
power surge, a battery
failure, or for other
reasons. The controller
is reinitializing the
NVRAM
Restrict and Migrate
2328 The NVRAM has
corrupt data
Warning The NVRAM has
corrupt data. The
controller is unable to
correct the situation
Restrict and Migrate
2329 SAS port report Warning The text for this alert is
generated by the
controller and can vary
depending on the
situation.
Restrict and Migrate
2337 The controller is
unable to recover
cached data from the
battery backup unit
(BBU)
Critical The controller was
unable to recover data
from the cache.
Restrict
2340 The background
initialization (BGI)
completed with
uncorrectable errors
Critical The background
initialization task
encountered errors
that cannot be
corrected.
Restrict and Migrate
2342 The Check
Consistency found
inconsistent parity
data. Data redundancy
may be lost
Warning The data on a source
disk and the redundant
data on a target disk is
inconsistent.
Restrict and Migrate
2349 A bad disk block could
not be reassigned
Critical A write operation
could not complete
Restrict
22