User's Manual
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
2310 A virtual disk is
permanently degraded
Critical A redundant virtual
disk has lost
redundancy. This may
occur when the virtual
disk suffers the failure
of more than one
physical disk.
Restrict and Migrate
2312 A power supply in the
enclosure has an AC
failure
Warning The power supply has
an AC failure
Restrict
2313 A power supply in the
enclosure has a DC
failure
Warning The power supply has
a DC failure.
Restrict
2314 The initialization
sequence of SAS
components failed
during system startup.
SAS management and
monitoring is not
possible.
Critical Storage Management
is unable to monitor or
manage SAS devices.
Restrict and Migrate
2318 Problems with the
battery or the battery
charger have been
detected. The battery
health is poor.
Warning The battery or the
battery charger is not
functioning properly.
Restrict
2319 Single-bit ECC error on
controller DIMM. The
DIMM is degrading.
Warning The dual in-line
memory module
(DIMM) is beginning to
malfunction.
Restrict and Migrate
2320 Single-bit ECC error.
The DIMM is critically
degraded.
Critical The DIMM is
malfunctioning. Data
loss or data corruption
may be imminent.
Restrict and Migrate
2321 Single-bit ECC error.
The controller DIMM is
nonfunctional. There
will be no further
reporting
Critical The dual in-line
memory module
(DIMM) is
malfunctioning. Data
loss or data corruption
is eminent.
Restrict and Migrate
2322 The DC power supply
is switched off
Critical The power supply unit
is switched off. Either
a user switched off the
Restrict and Migrate
21