User's Manual
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
power supply may
have failed.
2123 Redundancy Lost Warning A virtual disk or an
enclosure has lost
data redundancy.
Restrict and Migrate
2125 Controller cache
pinned for missing or
offline VD
Warning Controller getting
disconnected from its
VD, while IO is
happening
Restrict
2129 BGI (Back Ground
Initialization) Failed
Error
Critical BGI of a virtual disk
has failed.
Restrict
2137 Communication Time-
out Warning
Warning The controller is
unable to
communicate with an
enclosure.
Restrict and Migrate
2145 Controller battery low Warning The controller battery
charge is low.
Restrict
2169 The controller battery
needs to be replaced
Critical The controller battery
cannot recharge. The
battery may have been
already recharged the
maximum number of
times. In addition, the
battery charger may
not be working.
Restrict and Migrate
2171 The controller battery
temperature is above
normal
Warning The room temperature
may be too hot. The
system fan may also
be degraded or failed.
Restrict
2174 The controller battey
has been removed
Warning The controller cannot
communicate with the
battery. The battery
may be removed or the
contact point maye
degraded
Restrict and Migrate
2178 The controller battery
Learn cycle has timed
out
Warning The controller battery
must be fully charged
before the Learn cycle
can begin.
Restrict
17