User's Manual

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
1353 Power supply detected
a warning
Warning A power supply sensor
reading in the
specified system
exceeded definable
warning threshold.
Restrict
1354 Power supply detected
a failure
Error A power supply has
been disconnected or
has failed.
Restrict
1403 Memory Device Status
Warning
Warning A memory device
correction rate
exceeded an
acceptable value.
Restrict
1404 Memory Device Error Error A memory device
correction rate
exceeded an
acceptable value, a
memory spare bank
was activated, or a
multibit ECC error
occurred.
Restrict and Migrate
1703 Battery sensor
detected a warning
value
Warning A battery sensor in the
specified system
detected that a battery
is in a predictive
failure state.
Restrict
2048 Device Failed Error Critical A storage component
such as a physical disk
or an enclosure has
failed. The failed
component may have
been identified by the
controller while
performing a task such
as a rescan or a check
consistency.
Restrict and Migrate
2056 Virtual Disk Failed Critical One or more physical
disks included in the
virtual disk have failed.
Restrict and Migrate
2057 Virtual Disk Degraded
Warning
Warning This alert message
occurs when a
physical disk included
in a redundant virtual
disk fails.
Restrict