User's Manual

34 Using Dell Performance Resource Optimization Pack
2337 The controller
is unable to
recover
cached data
from the
battery
backup unit
(BBU)
Critical The controller was
unable to recover data
from the cache.
Restrict
2340 The
background
initialization
(BGI)
completed
with
uncorrectable
errors
Critical The background
initialization task
encountered errors
that cannot be
corrected.
Restrict and
Migrate
2342 The Check
Consistency
found
inconsistent
parity data.
Data
redundancy
may be lost
Warning The data on a source
disk and the
redundant data on a
target disk is
inconsistent.
Restrict and
Migrate
2349 A bad disk
block could
not be
reassigned
during a write
operation
Critical A write operation
could not complete
because the disk
contains bad disk
blocks that could not
be reassigned. Data
loss may have
occurred.
Restrict
Table 2-1. Alert Cause and Recovery Action
(continued)
Dell Event ID Alert
Description on
SCOM/ SCE
and PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 34 Tuesday, October 4, 2011 6:58 PM