User's Manual

32 Using Dell Performance Resource Optimization Pack
2318 Problems with
the battery or
the battery
charger have
been
detected. The
battery health
is poor.
Warning The battery or the
battery charger is not
functioning properly.
Restrict
2319 Single-bit
ECC error on
controller
DIMM.
Warning The dual in-line
memory module
(DIMM) is beginning
to malfunction.
Restrict and
Migrate
2320 Single-bit
ECC error
Critical The dual in-line
memory module
(DIMM) is
malfunctioning.
Restrict and
Migrate
2321 Single-bit
ECC error.
The controller
DIMM is
nonfunctional
. There will be
no further
reporting
Critical The dual in-line
memory module
(DIMM) is
malfunctioning. Data
loss or data corruption
is eminent.
Restrict and
Migrate
Table 2-1. Alert Cause and Recovery Action
(continued)
Dell Event ID Alert
Description on
SCOM/ SCE
and PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 32 Tuesday, October 4, 2011 6:58 PM