User's Manual
28 Using Dell Performance Resource Optimization Pack
2272 Patrol Read
found an
uncorrectable
media error
Critical The Patrol Read task
has encounted an error
that cannot be
corrected. There may
be a bad disk block
that cannot be
remapped.
Restrict and
Migrate
2273 A block on the
physical disk
has been
punctured by
the controller
Critical The controller
encountered an
unrecoverable
medium error when
attempting to read a
block on the physical
disk and marked that
block as invalid.
Restrict and
Migrate
2282 Hot spare
SMART
polling failed
Critical The controller
firmware attempted to
do SMART polling on
the hot spare but was
not able to complete
the SMART polling.
Restrict and
Migrate
2283 A redundant
path is broken
Warning The controller has two
connectors that are
connected to the same
enclosure.
Restrict and
Migrate
2289 Multi-bit
ECC error on
controller
DIMM
Critical An error involving
multiple bits has been
encountered during a
read or write
operation.
Restrict and
Migrate
Table 2-1. Alert Cause and Recovery Action
(continued)
Dell Event ID Alert
Description on
SCOM/ SCE
and PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 28 Tuesday, October 4, 2011 6:58 PM