User's Manual
Using Dell Performance Resource Optimization Pack 27
2213 Recharge
count
maximum
exceeded
Warning A virtual disk or an
enclosure has lost data
redundancy. In the
case of a virtual disk,
one or more physical
disks included in the
virtual disk have
failed.
Restrict
2246 The controller
battery is
degraded
Warning The temperature of
the the battery is high.
This maybe due to the
battery being charged.
Restrict
2264 A device is
missing
Warning The controller cannot
communicate with a
device. The device
may be removed.
Restrict
2265 A device is in
an unknown
state
Warning The controller cannot
communicate with a
device. The state of
the device cannot be
determined.
Restrict and
Migrate
2268 Storage
Management
communicatio
n Error
Critical Storage Management
has lost
communication with a
controller. This may
occur if the controller
driver or firmware is
experiencing a
problem.
Restrict and
Migrate
Table 2-1. Alert Cause and Recovery Action
(continued)
Dell Event ID Alert
Description on
SCOM/ SCE
and PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 27 Tuesday, October 4, 2011 6:58 PM