User's Manual

26 Using Dell Performance Resource Optimization Pack
2187 Single-bit
ECC error
limit exceeded
on the
controller
DIMM
Warning The controller
memory is
malfunctioning.
Restrict and
Migrate
2201 A global hot
spare failed
Warning The controller is not
able to communicate
with a disk that is
assigned as a global
hot spare. The disk
may have failed or
been removed.
Restrict
2203 A dedicated
hot spare
failed
Warning The controller is not
able to communicate
with a disk that is
assigned as a
dedicated hot spare.
Restrict
2206 The only hot
spare available
is a SATA disk.
SATA disks
cannot replace
SAS disks
Warning The only physical disk
available to be
assigned as a hot spare
is using SATA
technology.
Restrict
2207 The only hot
spare available
is a SAS disk.
SAS disks
cannot replace
SATA disks
Warning The only physical disk
available to be
assigned as a hot spare
is using SAS
technology.
Restrict
Table 2-1. Alert Cause and Recovery Action
(continued)
Dell Event ID Alert
Description on
SCOM/ SCE
and PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 26 Tuesday, October 4, 2011 6:58 PM