24 Using Dell Performance Resource Optimization Pack
2112 Enclosure
shutdown
Critical The physical disk
enclosure is either
hotter or cooler than
the maximum or
minimum allowable
temperature range.
Restrict and
Migrate
2122 Redundancy
degraded
Warning One or more of the
enclosure components
has failed. For
example, a fan or
power supply may
have failed.
Restrict
2123 Redundancy
Lost
Warning A virtual disk or an
enclosure has lost data
redundancy.
Restrict and
Migrate
2125 Controller
cache pinned
for missing or
offline VD
Warning Controller getting
disconnected from its
VD, while IO is
happening
Restrict
2129 BGI (Back
Ground
Initialization)
Failed Error
Critical BGI of a virtual disk
has failed.
Restrict
2137 Communicati
on Time-out
Wa rn in g
Warning The controller is
unable to
communicate with an
enclosure.
Restrict and
Migrate
Table 2-1. Alert Cause and Recovery Action