User's Manual

22 Using Dell Performance Resource Optimization Pack
2048 Device Failed
Error
Critical A storage component
such as a physical disk
or an enclosure has
failed. The failed
component may have
been identified by the
controller while
performing a task such
as a rescan or a check
consistency.
Restrict and
Migrate
2056 Virtual Disk
Failed
Critical One or more physical
disks included in the
virtual disk have
failed.
Restrict and
Migrate
2057 Virtual Disk
Degraded
Wa rn in g
Warning This alert message
occurs when a physical
disk included in a
redundant virtual disk
fails.
Restrict
2076 Virtual Disk
Check
Consistency
Failed
Critical A physical disk
included in the virtual
disk failed or there is
an error in the parity
information.
Restrict
2082 Virtual Disk
Rebuild
Failure
Error A physical disk
included in the virtual
disk has failed or is
corrupt.
Restrict
Table 2-1. Alert Cause and Recovery Action
(continued)
Dell Event ID Alert
Description on
SCOM/ SCE
and PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 22 Tuesday, October 4, 2011 6:58 PM