User's Manual
20 Using Dell Performance Resource Optimization Pack
1054 Temperature
sensor
detected a
failure value
Error A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier
in the specified system
exceeded its failure
threshold value.
Restrict and
Migrate
1104 Fan sensor
detected a
failure value
Error A fan sensor in the
specified system
detected the failure of
one or more fans.
Restrict
1154 Voltage sensor
detected a
failure value
Error A voltage sensor in the
specified system
exceeded its failure
threshold value.
Restrict and
Migrate
1203 Current
sensor
detected a
warning value
Warning A current sensor in the
specified system
exceeded its warning
threshold value.
Restrict
1204 Current
sensor
detected a
failure value
Error A current sensor in the
specified system
exceeded its failure
threshold value.
Restrict and
Migrate
1305 Redundancy
degraded
Warning A power supply sensor
reading in the
specified system
exceeded a warning
threshold.
Restrict
1306 Redundancy
lost
Error A power supply has
been disconnected or
has failed.
Restrict
Table 2-1. Alert Cause and Recovery Action
(continued)
Dell Event ID Alert
Description on
SCOM/ SCE
and PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 20 Tuesday, October 4, 2011 6:58 PM