10 Introduction
Table 1-1describes the sequence of events that occur in PRO Tip
management.
For more information on the type of events and the associated remedial
actions, see
Alerts and Recovery Actions
.
Table 1-1. Sequence of events with description
Sequence Number Event
1 Operations Manager agents on the host are enabled to
detect the warning, error, or failure alerts that are
generated by OMSA.
2 Alert is sent to Operations Manager.
3 Operations Manager console displays active PRO
alerts.
4 Operations Manager notifies the alert and the
associated PRO Tip ID to SCVMM.
5 SCVMM displays a corresponding entry in the
PRO Tip window with remedial action.
6 Implement the PRO Tip to enable recovery action on
the managed system by placing the managed system in
the Restrict mode, or Restrict and Migrate mode.
system.
7 SCVMM notifies Operations Manager about the
successful completion of the recovery action.
8 The SCVMM console displays the status of the PRO
Tip as Resolved after it is successfully implemented.
9 PRO Tip disappears from SCVMM PRO Tip window.
10 PRO Active alert disappears from SCOM.