User's Manual
Using Dell PRO Pack 43
2329 SAS port report Warning The text for this alert is
generated by the
controller and can vary
depending on the
situation.
Restrict and Migrate
2337 The controller is
unable to
recover cached
data from the
battery backup
unit (BBU).
Critical The controller was
unable to recover data
from the cache.
Restrict
2340 The background
initialization
(BGI)
completed with
uncorrectable
errors.
Critical The background
initialization task
encountered errors that
cannot be corrected.
Restrict and Migrate
2342 The Check
Consistency
found
inconsistent
parity data. Data
redundancy may
be lost.
Warnin g The data on a sou rce
disk and the redundant
data on a target disk is
inconsistent.
Restrict and Migrate
2349 A bad disk block
could not be
reassigned
during a write
operation.
Critical A write operation could
not complete because
the disk contains bad
disk blocks that could
not be reassigned. Data
loss may have occurred.
Restrict
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 43 Thursday, December 10, 2009 12:36 PM