User's Manual

40 Using Dell PRO Pack
2302 The enclosure is
not responding
Critical The enclosure or an
enclosure component is
in a Failed or Degraded
state.
Restrict and Migrate
2306 Bad block table
is full
Warning The bad block table is
the table used for
remapping bad disk
blocks. This table fills
as bad disk blocks are
remapped.
Restrict
2307 Bad block table
is full.
Critical The bad block table is
the table used for
remapping bad disk
blocks.
Restrict
2310 A virtual disk is
permanently
degraded
Critical A redundant virtual
disk has lost
redundancy. This may
occur when the virtual
disk suffers the failure
of more than one
physical disk.
Restrict and Migrate
2312 A power supply
in the enclosure
has an AC
failure
Warning The power supply has
an AC failure
Restrict
2313 A power supply
in the enclosure
has a DC failure
Warning The power supply has a
DC failure.
Restrict
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 40 Thursday, December 10, 2009 12:36 PM