36 Using Dell PRO Pack
2201 A global hot
spare failed
Warning The controller is not
able to communicate
with a disk that is
assigned as a global hot
spare. The disk may
have failed or been
removed.
Restrict
2203 A dedicated hot
spare failed
Warning The controller is not
able to communicate
with a disk that is
assigned as a dedicated
hot spare.
Restrict
2206 The only hot
spare available is
a SATA disk.
SATA disks
cannot replace
SAS disks
Warning The only physical disk
available to be assigned
as a hot spare is using
SATA technology.
Restrict
2207 The only hot
spare available is
a SAS disk. SAS
disks cannot
replace SATA
disks
Warning The only physical disk
available to be assigned
as a hot spare is using
SAS technology.
Restrict
2213 Recharge count
maximum
exceeded
Warni ng A vi rt ua l d is k or an
enclosure has lost data
redundancy. In the case
of a virtual disk, one or
more physical disks
included in the virtual
disk have failed.
Restrict
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 36 Thursday, December 10, 2009 12:36 PM