User's Manual
Using Dell PRO Pack 35
2145 Controller
battery low
Warning The controller battery
charge is low.
Restrict
2169 The controller
battery needs to
be replaced
Critical The controller battery
cannot recharge. The
battery may have been
already recharged the
maximum number of
times. In addition, the
battery charger may not
be working.
Restrict and Migrate
2171 The controller
battery
temperature is
above normal.
Warning The room temperature
may be too hot. The
system fan may also be
degraded or failed.
Restrict
2174 The controller
battey has been
removed.
Warning The controller cannot
communicate with the
battery. The battery
may be removed or the
contact point maye
degraded
Restrict and Migrate
2178 The controller
battery Learn
cycle has timed
out
Warning The controller battery
must be fully charged
before the Learn cycle
can begin.
Restrict
2187 Single-bit ECC
error limit
exceeded on the
controller
DIMM
Warning The controller memory
is malfunctioning.
Restrict and Migrate
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action