User's Manual

34 Using Dell PRO Pack
2112 Enclosure
shutdown
Critical The physical disk
enclosure is either
hotter or cooler than
the maximum or
minimum allowable
temperature range.
Restrict and Migrate
2122 Redundancy
degraded
Warning One or more of the
enclosure components
has failed. For example,
a fan or power supply
may have failed.
Restrict
2123 Redundancy
Lost
Warni ng A vi rt ua l d is k or an
enclosure has lost data
redundancy.
Restrict and Migrate
2125 Controller cache
pinned for
missing or
offline VD
Warning Controller getting
disconnected from its
VD, while IO is
happening
Restrict
2129 BGI (Back
Ground
Initialization)
Failed Error
Critical BGI of a virtual disk
has failed.
Restrict
2137 Communication
Time-out
Wa rn i ng
Warning The controller is
unable to
communicate with an
enclosure.
Restrict and Migrate
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 34 Thursday, December 10, 2009 12:36 PM