User's Manual
30 Using Dell PRO Pack
1054 Temperature
sensor detected
a failure value
Error A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier in
the specified system
exceeded its failure
threshold value.
Restrict and Migrate
1104 Fan sensor
detected a
failure value.
Error A fan sensor in the
specified system
detected the failure of
one or more fans.
Restrict
1154 Voltage sensor
detected a
failure value.
Error A voltage sensor in the
specified system
exceeded its failure
threshold value.
Restrict and Migrate
1203 Current sensor
detected a
warning value.
Warning A current sensor in the
specified system
exceeded its warning
threshold value.
Restrict
1204 Current sensor
detected a
failure value.
Error A current sensor in the
specified system
exceeded its failure
threshold value.
Restrict and Migrate
1305 Redundancy
degraded.
Warning A power supply sensor
reading in the specified
system exceeded a
warning threshold.
Restrict
1306 Redundancy
lost.
Error A power supply has
been disconnected or
has failed.
Restrict
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
book.book Page 30 Thursday, December 10, 2009 12:36 PM