User's Manual

Using Dell PRO Pack 29
This verifies that the overridden recovery action is successful.
Figure 3-7. Override Recovery Action
Alert Cause and Recovery Action
The following table lists the alerts and the corresponding recommended
remedial action:
Restrict: It is recommended that the server should be temporarily unavailable
for placement of new VMs until the maintenance tasks have been completed.
Restrict and Migrate: In this mode, in order to prevent loss of service from
the virtual workloads, it is recommended that all running VMs be migrated
from the server to another healthy server immediately.
Table 3-1. Alert Cause and Recovery Action
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
1053 Temperature
sensor detected
a warning value
Warning A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier in
the specified system
exceeded its warning
threshold value.
Restrict