User's Manual

28 Using Dell PROPack
1703 Battery sensor
detected a
warning value.
Warning A battery sensor in the
specified system
detected that a battery
is in a predictive failure
state.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
2048 Device Failed
Error.
Error A storage component
such as a physical disk
or an enclosure has
failed.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
2056 Virtual Disk
Failed Warning.
Error One or more physical
disks included in the
virtual disk have failed.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
2057 Virtual Disk
Degraded
Wa rn i ng
Warning This alert message
occurs when a physical
disk included in a
redundant virtual disk
fails.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action