User's Manual

Using Dell PROPack 27
1353 Power supply
detected a
warning.
Warning A power supply sensor
reading in the specified
system exceeded
definable warning
threshold.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
1354 Power supply
detected a
failure.
Error A power supply has
been disconnected or
has failed.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
1403 Memory Device
Status Warning
Warning A memory device
correction rate
exceeded an acceptable
value.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
1404 Memory Device
Error.
Error A memory device
correction rate
exceeded an acceptable
value, a memory spare
bank was activated, or a
multibit ECC error
occurred.
In SCVMM, PRO
Tip implementation
migrates running
virtual machines
from unhealthy host
to healthy host(s).
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action