User's Manual
26 Using Dell PROPack
1203 Current sensor
detected a
warning value.
Warning A current sensor in the
specified system
exceeded its warning
threshold value.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
1204 Current sensor
detected a
failure value.
Error A current sensor in the
specified system
exceeded its failure
threshold value.
In SCVMM, PRO
Tip implementation
migrates running
virtual machines
from unhealthy host
to healthy host(s).
1305 Redundancy
degraded.
Warning A power supply sensor
reading in the specified
system exceeded a
warning threshold.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
1306 Redundancy
lost.
Error A power supply has
been disconnected or
has failed.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
Table 3-1. Alert Cause and Recovery Action
(continued)
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action