User's Manual
Using Dell PROPack 25
Alert Cause and Recovery Action
The following table lists the alert and the corresponding recommended
remedial action:
Table 3-1. Alert Cause and Recovery Action
Dell
Event
ID
Alert Description
in SCOM/ SCE &
PRO Tip in
SCVMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
1053 Temperature
sensor detected
a warning value
Warning A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier in
the specified system
exceeded its warning
threshold value.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
1054 Temperature
sensor detected
a failure value
Error A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier in
the specified system
exceeded its failure
threshold value.
In SCVMM, PRO
Tip implementation
migrates running
virtual machines
from unhealthy host
to healthy host(s).
1104 Fan sensor
detected a
failure value.
Error A fan sensor in the
specified system
detected the failure of
one or more fans.
In SCVMM, PRO
Tip implementation
places the host in
Maintenance mode
so that it is no longer
available for new
virtual machine
placements.
1154 Voltage sensor
detected a
failure value.
Error A voltage sensor in the
specified system
exceeded its failure
threshold value.
In SCVMM, PRO
Tip implementation
migrates running
virtual machines
from unhealthy host
to healthy host(s).