User's Manual
Understanding Dell Server Management Pack Suite Operations 51
• Event ID = Actual event ID of the Server Administrator Storage
Management Service event
• Severity = Severity of the actual event
• Data Provider = Windows system event log
DRAC / CMC
All informational, warning, and critical SNMP traps for the DRAC/CMC have
a corresponding SNMP trap rule.
Each of these rules are processed based on the following criteria:
• Source Name = "DRAC/CMC name/ip"
• OID = Actual trap ID of the DRAC SNMP trap event
• Severity = Severity of the actual event
• Data Provider = SNMP trap
Performance Collection Rules
There are seven performance collection rules that collect information on the
following parameters:
• Amperage Per Power supply
• Power Consumption (Watts)
• Power Consumption (in BTU/hr)
• Energy Consumption
•Peak Power
•Peak Amperage
• Ambient Temperature
In the Operations Console, Dell→ Performance and Power Monitoring
Views displays the performance information that is collected from Dell
Systems. This feature is available on installation of Scalable Server
Management Pack. By default this feature is disabled. To enable this feature
perform the following:
1
Open the
Authoring
pane in the Operations Console.
2
Select
Rules
.
3
Right-click the rule you want to enable.