Owner's Manual
file:///T|/htdocs/SOFTWARE/smconect/msscom/40/en/readme/DellMPv40_Server_Readme.txt[10/19/2012 1:39:51 PM]
Management utility (BMU) 2.0 or later should be installed on the
SCOM management server. BMC tasks use default credentials including
the default BMC install path (c:\program Files\Dell\SysMgt\bmc).
For IPMI Shell errors, see the "Dell OpenManage Baseboard Management
Utilities User's Guide" from the "Dell Systems Management Tools and
Documentation DVD" or from the Dell Support website at
"support.dell.com".
* To run the Remote Power Control tasks or the LED Identification
Control tasks on managed systems, the BMC Management Utility
version 2.0 or later must be installed on the management station.
Please note that BMC Management utility (BMU) 2.0 or later should be
installed on SCOM management server in order to carry out the remote
power control tasks. BMC tasks use default credentials including the
default BMC install path (c:\program Files\Dell\SysMgt\bmc).
In OM 5.3 to 6.1 the BMU is included on the "Dell Systems Management
Tools and Documentation DVD".
* If the DRAC Console launch gives you a "Page cannot be displayed"
error, ensure that there is network connectivity from the device
(DRAC/iDRAC card), and that the device is configured with a valid
IP address.
* If attributes or hardware objects do not display for Dell systems,
ensure that the CIM Dell namespace is not corrupted and that the Dell
Services are not down. Restart the Dell managed system or reinstall
Server Administrator to correct the CIM behavior.
* Remote Power control tasks, LED Identification control tasks, and
Clear Agent ESM Log will function only for Dell systems on which a
Dell Agent is installed.
NOTE: The Operations Manager 2007 SP1 Management Server Action
account needs administrator privileges on all Dell managed
systems to perform DRAC in-band object discovery and launch the
Dell Remote Access Console task. If the Management Server
Action account has normal user privileges, operators need to
provide task credentials with Power User (or higher) privileges
to run the Clear ESM Logs task, instead of selecting 'Use the
predefined Run as Account'.
#####################################################################
KNOWN ISSUES
#####################################################################
- The server attribute "Life Cycle Controller size" is always listed
as 'Not available'.(DF304827)
#####################################################################
Information in this document is subject to change without notice.
(C) 2007-2009 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission